Enter your username:
Do you want to login or register?
  • Forgot your password?

    Login / Register




    Page 1 of 2 1 2 LastLast
    Results 1 to 20 of 25
    1. #1
      Join Date
      Aug 2004
      Location
      San Antonio, Tx
      Posts
      1,193

      C5 fuel tanks into 1st gen

      has anyone ever seen C5 or C6 fuel tanks in a first gen camaro? since there isn't anything close to stock on my '69 camaro i figured why not look into it since i have the room to put it in and they are pretty cheep.

      pros:
      proven design on road tracks to run low levels of fuel.
      moves weight in front of the rear wheels.
      easy to get replacement parts if something were to happen on the road
      lightweight
      protected better than in the stock location

      cons:
      packaging, would need to build a sealed from the passenger compartment firewall thats still serviceable top or bottom.

      ok so i can only think of one drawback.
      Instagram: CamaroAJ

    2. #2
      Join Date
      May 2002
      Location
      Northern California
      Posts
      10,716
      Country Flag: United States
      the tanks are designed for the vette body, sure they might fit somewhere but then why not just have a tank built to fit the corvette tank module then its about time vesus effort = what reward? Not too much benefit over any of the tanks out there.

      We thought about building a tank to sit right under the package tray but after going over the numbers it was not worth losing some center of gravity height over.


      Vince
      MrQuick ΜΟΛ'ΩΝ ΛΑΒ'Ε


    3. #3
      Join Date
      Jun 2005
      Location
      Lynnwood Wa.
      Posts
      248
      Country Flag: United States
      Modify the stock tank with a LS1 fuel pump module
      http://www.vetteworksonline.com/ls1_conversion_fuel.htm
      Oliver Shultz
      It's OK to giggle and snicker. don't laugh and point

    4. #4
      Join Date
      Jul 2006
      Location
      Pensacola, FL
      Posts
      1,265
      Country Flag: United States
      I have an F-body pump assembly if you are interested in doing the conversion.
      Scott

    5. #5
      Join Date
      Aug 2004
      Location
      San Antonio, Tx
      Posts
      1,193
      Quote Originally Posted by MrQuick View Post
      time vesus effort = what reward? Not too much benefit over any of the tanks out there.

      We thought about building a tank to sit right under the package tray but after going over the numbers it was not worth losing some center of gravity height over.
      benefit for me would be a proven tank for under $150.

      your right about a tank under the package tray messing up the numbers. i was thinking more along the lines of just behind the seats, so roughly a foot and a half lower and about three feet forward of the package tray. that would put the tanks lower than stock and in front of the rear axle.

      i've had many of these tanks out so i have a rough measurements on them. it would be very easy to make them mount and fit safe, the tricky part it to make them also easy to service.
      Instagram: CamaroAJ

    6. #6
      Join Date
      Aug 2004
      Location
      San Antonio, Tx
      Posts
      1,193
      Quote Originally Posted by Z06vet View Post
      I have an F-body pump assembly if you are interested in doing the conversion.
      Scott
      got one from the donor car, thanks though.
      Instagram: CamaroAJ

    7. #7
      Join Date
      Jun 2001
      Location
      Newbury Park, CA
      Posts
      5,839
      Country Flag: United States
      If mounting them behind the front seats is a consideration a method to have them mount external to the cabin is a should be used. The last thing you want is a bunch of fuel that could leak into the cabin.
      VaporWorx. We Give You Gas http://www.vaporworx.com

    8. #8
      Join Date
      Aug 2004
      Location
      San Antonio, Tx
      Posts
      1,193
      the floor pans would be modified in such a way that if a tank did leak it would be out the bottom. my only issue that i am thinking of a way to over come is getting the tanks in and out of the car. i could build a fully welded top and then cut the floor pans out betwen the DSE sub frame connectors, and a inch or so front and rear of the tanks. then do what GM does with the tank and use the bottom shield to hold the tanks up and in place.

      its a lot of work to do but its fun for me and i would still have less money in it than buying a tank. more measuring will need to be done but it will need to wait until the seats are mounted and the rear suspension is in.
      Instagram: CamaroAJ

    9. #9
      Join Date
      Oct 2007
      Posts
      1,872
      what about exhaust>> if i understand your idea correctlty
      From a place you will not see comes a sound you will not hear....

      67 Camaro In progress

      https://www.pro-touring.com/showthre...-Tap-67-camaro

    10. #10
      Join Date
      Aug 2004
      Location
      San Antonio, Tx
      Posts
      1,193
      what about it? it would run the normal way it does now just the mufflers can be mounted where the stock tank once was.
      Instagram: CamaroAJ

    11. #11
      Join Date
      May 2002
      Location
      Northern California
      Posts
      10,716
      Country Flag: United States
      AJ, which pump has the sender...or is it the transfer pump to the main pump/sender module?

      I suppose if you can get them cheap it would be good to use. But I think you can do better with the shape.
      MrQuick ΜΟΛ'ΩΝ ΛΑΒ'Ε


    12. #12
      Join Date
      Aug 2004
      Location
      San Antonio, Tx
      Posts
      1,193
      Vince, there is a sender in each tank. the left tank is the primary tank and the right tank is the secondary. the jet/venturi design pulls fuel from both tanks at the same time so the car is kept balanced.

      here is a pretty good bit of info on the fuel system http://www.c5help.com/fueltank.htm
      Instagram: CamaroAJ

    13. #13
      Join Date
      May 2002
      Location
      Northern California
      Posts
      10,716
      Country Flag: United States
      thanks buddy, great site. lots of good information.
      MrQuick ΜΟΛ'ΩΝ ΛΑΒ'Ε


    14. #14
      Join Date
      Aug 2004
      Location
      San Antonio, Tx
      Posts
      1,193
      no problem.

      also i got to thinking, the fuel is used in one tank before the other. i was thinking of a mod we did to another tank. we drilled the bottom side of both tanks and ran a connecting jumper between them. had to do that when we installed frame mounted fuel pumps for the twin turbo engine.
      Instagram: CamaroAJ

    15. #15
      Join Date
      May 2002
      Location
      Northern California
      Posts
      10,716
      Country Flag: United States
      but what did you guys use for a transfer tube and what sealer to use on abs?

      MrQuick ΜΟΛ'ΩΝ ΛΑΒ'Ε



    16. #16
      Join Date
      Jul 2006
      Location
      Indianapolis, IN
      Posts
      350
      Quote Originally Posted by CamaroAJ View Post
      Vince, there is a sender in each tank. the left tank is the primary tank and the right tank is the secondary. the jet/venturi design pulls fuel from both tanks at the same time so the car is kept balanced.
      Unfortunately, this is not true and about the only draw back to the system as far as balance goes. Fuel is contantly pumped from the RS tank to the LS until there is no fuel left to occupy the RS tank.

      Here is a line from the link you posted mentioning this also. "The jet pump is able to move enough fuel to ensure that all of the fuel in the right tank is consumed before the level in the left tank begins to drop."

      Now you could add a bottom crossover as you mentioned to equalize things and still keep the venturi working. You could not do this in a C5 vette as it would set codes for the level senders not being happy.

      Hope this helps.

      Mike Norris
      Last edited by Mike Norris; 11-29-2010 at 06:12 AM.
      Mike Norris

    17. #17
      Join Date
      Apr 2009
      Location
      san diego
      Posts
      5,101
      Country Flag: United States
      What if you had a drive shaft failure? Sounds like a cool idea tho!

    18. #18
      Join Date
      Aug 2004
      Location
      Rustburg, Virginia
      Posts
      3,436
      Country Flag: United States
      Those tanks look really small...how much will they hold?
      1970 RS/SS350 139K on the clock:
      89 TPI motor w/ 1pc rear seal coupled to a Viper T56 via Mcleod's modular bellhousing w/ hydraulic T/O bearing from the Viper, 12 bolt rear w/ 3.73 gearing, SC&C upper control arms, factory lowers with Delalums, C5 brakes at all four corners, Front Wheels 17x8's with Sumi 255/40/17 and Rear Wheels 17x9's with Sumi 275/40/17.
      Brief description of the work done so far can be found here: http://www.nastyz28.com/forum/showthread.php?t=112454


    19. #19
      Join Date
      Aug 2004
      Location
      San Antonio, Tx
      Posts
      1,193
      Quote Originally Posted by MrQuick View Post
      but what did you guys use for a transfer tube and what sealer to use on abs?
      we used the bulkhead AN fittings with the nylon washers and 12AN hose. it never leaked and that was with E100 fuel.

      Quote Originally Posted by Mike Norris View Post
      Unfortunately, this is not true and about the only draw back to the system as far as balance goes. Fuel is contantly pumped from the RS tank to the LS until there is no fuel left to occupy the RS tank.

      Now you could add a bottom crossover as you mentioned to equalize things and still keep the venturi working. You could not do this in a C5 vette as it would set codes for the level senders not being happy.
      i corrected myself in another post. the mod we did was in a C6Z, IIRC we were setting codes because of the transfer rate and it shutting off the fuel gauge. i can't remember what we did to fix that issue but i know we got it taken care of.

      in my car i could modify the fuel level sender to work with the '01 camaro system i'm running. something like hooking the cards in series and one card would be full to half tank and the other would be half tank to empty tank. that would be pretty easy to do really.

      Quote Originally Posted by Bryce View Post
      What if you had a drive shaft failure? Sounds like a cool idea tho!
      it was in a C6Z so the torque tube would contain the drive shaft. not sure it would work if i got them to fit in my car.

      Quote Originally Posted by John Wright View Post
      Those tanks look really small...how much will they hold?
      18g total.
      Instagram: CamaroAJ

    20. #20
      Join Date
      Jun 2001
      Location
      Newbury Park, CA
      Posts
      5,839
      Country Flag: United States
      You could swap the tanks right-to-left. The balance would get better as fuel is used up in the LH tank. You could use the weight of the gasoline to balance the car with you in the drivers seat. It would simplify things since only the venturi transfer line would be necessary.
      VaporWorx. We Give You Gas http://www.vaporworx.com

    Page 1 of 2 1 2 LastLast



    Advertise on Pro-Touring.com